This exception will allow the minimum thickness to be 4 2 at the low point or 5 2 4 away from the drain on a per foot tapered system.
Roof insulation r value thickness.
Note from this chart that the ideal r value differs for each part of your home.
Add the results for all the materials together to get the total r value for the roof assembly.
2 layers of 1 40 iso 16 0 r value vs 2 layers of 1 60 iso 18 2 r value isogard hd board 2 5 r value vs gypsum 28 total r value 18 5 vs total r value 18 48 utilizing the firestone isogard hd cover board helps reduce the thickness of the initial layers of insulation and thereby reduces the costs of the project.
Typical recommendations for exterior walls are r 13 to r 23 while r 30 r 38 and r 49 are common for ceilings and attic spaces.
Zone 6 requires an r 30 minimum which is 5 2 thick.
Firestone isogard polyiso insulation goes even further and was the first product on the market to meet both astm c1289 required and recommended thermal performance values.
But what does that mean and how do researchers determine r value.
None of the available insulating materials will fit within the depth of a 90 mm rafter but by selecting a 140 mm deep rafter it is possible to fit a wider choice of products including r values that exceed the minimum see figure 2.
Fm approved subject to the conditions of approval as a roof insulation when installed as shown in the current edition of the factory mutual research approvals guide.
Hunter panels roofing tech topic r105.
Recognized by the iecc.
For each different material multiply the thickness by the standard r value per inch for that material.
To calculate the total r value of a roof assembly find the total thickness in inches of each type of insulating material within the system.
To compare different insulation products researchers have to create the exact same conditions and then measure how well the insulation performs.
The table below shows what levels of insulation are cost effective for different climates and.
For example if you have a type of insulation that has an r value of r 5 per inch of thickness you will need a depth of 6 inches of this insulation installed in your attic to reach r 30 if you live in zones 2 or 3.
At one inch thickness enerfoil tm achieves a 6 2 r value or a 1 08 rsi.
Insulation level are specified by r value.
Excellent lttr value compared to any other fm class 1 rated products of equivalent thickness.
Firestone iso 95 gl polyiso insulation has a higher r value than other insulation products while also outperforming competitive polyiso at low temperature.
Depending on where you live and the part of your home you re insulating walls crawlspace attic etc you ll need a different r value.
Recommended home insulation r values.
The higher the r value the better the thermal performance of the insulation.