The main advantage of sheathing a roof with plywood is that it goes on faster.
Roof sheathing over 1x6.
Sheathing is installed over multiple trusses rafters so it essentially turns them into one cohesive unit instead of individual structural members.
Took off about 200 sq ft of shingle and found where the leak was coming from.
Tiles were designed so that lugs or short protrusions on the top backside of each tile would hook over the step sheathing.
As roofing contractors in seattle we are often asked why do we need plywood over our old solid sheathing.
In my experience the need for tongue and groove or edge clips is determined by the thickness of the roof sheathing and the spacing of the rafters.
Anyway no plywood just 1 x 6.
I do not recommend 3 8 plywood for roof sheathing installed directly on the roof joists.
For instance a branch through the roof can be largely ignored just fix the finish roofing material and don t worry about a little hole in the sheathing.
No rot per se but the wood was a tad soft.
Roof sheathing provides an area where the surface material can be attached but it also helps keep the trusses and or rafters properly spaced.
Roof decks on homes built before 1970 are often 1 8 fir pre plywood shiplap.
After all sheathing has plenty of holes cut in it already for vents.
Small glitches have relatively easy remedies.
Roof deck 2x6 or 1x6 t g we use 1x6 up to 3 but the roof is then strapped after with 2x4 then sheathing.
Some use clips as convenient spacers.
Sometimes there are large gaps between the boards and a layer of osb or plywood is placed over the existing sheathing.
For 5 8 or thicker roof sheathing on 16 o c.
Rafters it shouldn t be an issue.
Until the 1940s exterior grade plywood was not available.
The keyword here is solid it used to be standard to use shiplap 1 boards tongue groove or other boards for the roof deck.
More recently however most roofers recommend solid sheathing on the roof to give the house additional resistance to movement or shear strength.
He 1 x 6 as sheathing no plywood roofing contractor talk.
Friend of mine had a big leak in his roof.
Sheathing works with other components of the roof as well.
On 24 1x6 will work but put a layer of sheathing down to eliminate the roofing nail issue.
It s a lot easier and cheaper to do spot repairs on board roofs than it is on plywood.
The roofer has been tearing the old roof off and has found that the sheathing is dimensional lumber.
Step sheathing can then be applied over the solid sheathing as needed.